Otamatea eHaus Euro

9,502
kg

This energy-efficient three-bedroom home has a generous 193sqm floor area, including an open plan living space, office, separate media room, and double garage with workshop. The impressive raking ceiling in the dining area provides a sense of space like no other and flows to the outdoor living space. But there's more to this house than just its beautiful design.

This home is an eHaus Euro, meeting our premium performance standard. It incorporates thicker walls (14cm vs standard 9cm), higher levels of insulation in the slab, walls, and ceiling, thermally broken aluminium joinery, and a Zehnder ventilation unit, all exceeding industry standards in energy efficiency and environmental impact.

The eHaus Whanganui team constructed the frames on-site, ensuring utmost control over thermal bridges and making necessary improvements along the way. The result was a home that not only looked spectacular but also performed exceptionally in terms of energy conservation and indoor comfort.

9,502

This project is making significant carbon savings for a better environment.

We believe that our homes should have a big impact on the way we live, but little impact on the land. We've calculated the amount of carbon our homes have saved through energy efficiency from move in day 'til now. At their core, eHaus' are built with the elimination of carbon emissions in mind - so we're not only creating healthy, comfy & high performing homes, but spaces that don't cost the earth.

Learn More

Meet the team of designers and builders behind this project

Our eHaus team is made up of some of the country's best Passive House builders, architects and designers who are redefining the way kiwis live one home at a time. Our team of professionals work together to see your dreams come to reality.
Experience
See this eHaus for yourself
Contact us

Design Components

Floor
Fully insulated concrete pad with a U-value of 0.182 W/(m²K)
Wall
140mm timber frame with a U-value of 0.201 W/(m²K)
Roof
Double layer of fibreglass insulation with a U-value of 0.137 W/(m²K)
WINDOW JOINERY FRAME
APL Altherm - Thermally Broken Aluminium with a U-value of 4.2 W/(m²K)
Glazing
Double glazed Argon with Ug-value of 1.12 W/(m²K) g-value of 61%
Ventilation
Zehnder ComfoAir Q350 MHRV
Hot Water
Bosch Compress 3000 - 270L capacity hot water heat pump

Performance Specs

Heating Demand: 11.5 kWh/(m²yr)
Heating Load: 10.7 W/m²
Frequency of Overheating: 2.6% year over 25℃
TFA: 174.89
Form Factor: 3.47
Air Leakage @50Pa: 0.47
Per Demand: 32.0 kWh/(m²yr)

Consultant

Maria Rei

Certifier

N/A