Bolton001

EHAUS EURO, PHI LOW ENERGY

Kapiti Waikanae Beach

Carbon Savings

13,212 KG

Heat Savings

87%

This home is built on 3 levels nestling well into the natural surroundings. With a garage and workshop downstairs, 3 bedrooms above that are connected to the open plan kitchen dining space. There is a private deck at the rear of the property giving great indoor outdoor flow.  Just a 1kW panel heater is sufficient to keep the home warm in winter and the solar PV system ensures minimum running costs throughout the year.

Meet the team Behind this project

Ross designhaus

Ross Bennett

Ross is a specialist in Passive House design and is located in the Manawatū, but works on projects around the country.

Design Components

Floor
EPS raft slab 200mm U-value = 0.184 W/(m²K) & Suspended timber floor – U-value = 0.222 W/(m²K)
Wall
140mm timber frame with service cavity U-value = 0.207W/(m²K)
Roof
Double layer of fibreglass insulation U-value = 0.141 W/(m²K)
Window Joinery Frame
uPVC U f-value = 1.50 W/(m²K)
Glazing
Double glazing U g-value = 1.1 W/(m²K) g -value = 61%
Ventilation
Zehnder ComfoAir 350 MHRV
Hot Water
Bosch Compress 3000 – 270L capacity hot water heat pump
Heating/Cooling
1 kW panel heater on thermostat
Power Generation
3,4kW solar photovoltaic array

Performance Specs

Heating Demand
27.7 kWh/(m²yr)
Heating Load
16.8W/m²
Frequency of Overheating
3.4%
TFA
117.9 m²
Form Factor
4.12
Air Leakage @ 50Pa
1.05 ACH
Per Demand
118 kWh/(m²yr)

Consultant: Birgit Bartel

Certifier: Non Certified