C2 MW0119 1

EHAUS EURO, PHI LOW ENERGY

Milverton

Carbon Savings

9,866 KG

Heat Savings

86%

Designed against the trend of building bigger, this 106sqm home prioritises quality over quantity. Its neat and compact layout encompasses two bedrooms, with the master featuring an adjoining walk-in wardrobe. The kitchen, dining, and living areas are thoughtfully integrated, creating a space that promotes comfort and efficiency, and the standalone 35sqm garage allows for additional storage. Thanks to its innovative design, this home has no heating installed, setting a new standard in energy efficiency. Clad in Linea weatherboard and fitted with uPVC window joinery, a fully insulated concrete pad, and a heat pump water heater, this home not only delivers on comfort but also ensures low power bills, making it a beacon of sustainability.
"

We love our new house! After spending some time, you start to notice the smaller details. These details indicate to me a great sense of pride, creativity, and a high standard of workmanship that you just don’t see every day.

"

— Graeme & Joanna Gillies

Meet the team Behind this project

Ross designhaus

Ross Bennett

Ross is a specialist in Passive House design and is located in the Manawatū, but works on projects around the country.

Design Components

Floor
Fully insulated concrete pad with a U-value of 0.184 W/(m²K)
Wall
140mm timber frame with service cavity U-value of 0.220 W/(m²K)
Roof
Double layer of fibreglass insulation U-value of 0.101 W/(m²K)
Window Joinery Frame
Advanced Windows NZ – uPVC- Uw value = 1.50 W/(m²K)
Glazing
Viridian- Double Glazed Argon Ug value=1.12 W/(m²K) G value = 61%
Ventilation
Zehnder Comfo Air 180 MHRV
Hot Water
Azzuro HP 330L heat pump water heater
Heating/Cooling
No heating installed

Performance Specs

Heating Demand
15.7 kWh/(m²yr)
Heating Load
11.6 W/m²
Frequency of Overheating
2.2 % year over 25C
TFA
92.6 m²
Form Factor
3.9
Air Leakage @ 50Pa
0.51 ACH
Per Demand
74 kWh/(m²yr)

Consultant: eHaus - Jon Iliffe

Certifier: Non Certified