eHaus Northland are giving away 2 free design concepts. Get all the details here.

Waikato - Chartwell Greenhill Park eHaus Pacific

6,183
kg

This 160 sqm, two bedroom, family home is not only warm and stylish but Award winning taking out Gold in the 2022 HOY awards.  Located on a corner site within its subdivision, the floor plan has been carefully considered to offer flexibility.  As you step inside you are lead through to a light and bright open-plan living and dining area.  Demonstrating adaptable and clever use of space, the living zone also serves as a music tuition area, with room for a grand piano.  Natural light spills into the modern kitchen and large doors open out from the main living area to a generous covered outdoor dining space.  A second living area, complete with office nook, serves as a multi-purpose space that could be a third bedroom.  The main bedroom, with ensuite and walk-in wardrobe, is a true retreat.

6,183

This project is making significant carbon savings for a better environment.

We believe that our homes should have a big impact on the way we live, but little impact on the land. We've calculated the amount of carbon our homes have saved through energy efficiency from move in day 'til now. At their core, eHaus' are built with the elimination of carbon emissions in mind - so we're not only creating healthy, comfy & high performing homes, but spaces that don't cost the earth.

Learn More

Meet the team of designers and builders behind this project

Our eHaus team is made up of some of the country's best Passive House builders, architects and designers who are redefining the way kiwis live one home at a time. Our team of professionals work together to see your dreams come to reality.
Experience
See this eHaus for yourself
Contact us

Design Components

Floor
Fully insulated concrete pad with a U-value of 0.182 W/(m²K)
Wall
SIPs Panel 165 - U-value of 0.223 W/(m²K)
Roof
Double layer of fibreglass insulation with a U-value of 0.131 W/(m²K)
Window Joinery Frame
APL Thermal Heart - Thermally broken aluminium - Uf value 4.00 W/(m²K)
Glazing
Metro Low-E Xtreme - Double Glazed Argon Ug value 1.10 W/(m²K) G Value 47%
Ventilation
Zehnder ComfoAir 180 MHRV
Hot Water
Hot Water heat Pump

Performance Specs

Heating Demand: 23.4 kWh/m²/yr
Heating Load: 16.2 W/m²
Frequency of Overheating: 2.2% year over 25C
TFA: 129.5 m2
Form Factor: 3.7
Air Leakage@50Pa: 0.58 ACH
PER Demand: 47 kWh/m²/yr