079 A5632 2 1

EHAUS PACIFIC

Raglan

Carbon Savings

4,749 KG

Heat Savings

82%

Presenting an eHaus Pacific, elegantly clad in Abodo and Colorsteel, this home offers a captivating open-plan living experience with stunning views overlooking the estuary. Featuring three bedrooms, including a master with its own ensuite, the thoughtful design boasts large doors that seamlessly connect the interior to an inviting alfresco dining area. Characterised by its well-organised, simplistic layout, polished concrete floors, and a charming coastal style, this eHaus stands as a testament to our commitment to creating homes that prioritise comfort and health.
"

We recently had the pleasure of working with eHaus Waikato to build our new home, and we couldn’t be happier with the experience. From start to finish, their team demonstrated outstanding attention to detail, reliability, and flexibility, all while maintaining a strong work ethic that made the entire process smooth and stress-free.

Not only did they complete the build on time, but every member of the team was a pleasure to deal with. Their craftsmanship is exceptional, and the final result speaks for itself - we absolutely love our home. The design has exceeded our expectations, providing an incredibly quiet and comfortable living space. We constantly receive compliments, and people are always asking who built it!

We highly recommend eHaus Waikato to anyone looking for a professional, high-quality builder who truly cares about their work.

"

— Alanna and Rolando

Meet the team Behind this project

Dean Baldock

Dean Baldock

Dean is a Waikato based architect who brings a collaborative, people-centered approach to architecture.

Design Components

Floor
Fully insulated concrete pad with a U-value of 0.182 W/(m²K)
Wall
140mm timber frame U-value of 0.309 W/(m²K)
Roof
Double layer of fibreglass insulation U-value of 0.129 W/(m²K)
Window Joinery Frame
APL Altherm
Glazing
AGP System Grey Solux-E Double Glazed Argon Ug value=1.1 W/(m²K) g- value = 42%

Performance Specs

Heating Demand
24.3 kWh/(m²yr)
Heating Load
18.1 W/m²
Frequency of Overheating
4.3% year over 25C
TFA
114.5m²
Form Factor
3.66
Air Leakage @ 50Pa
0.79 ACH
Per Demand
49 kWh/(m²yr)

Consultant: eHaus - Maria Rei

Certifier: N/A