Breath of fresh air: Join our free webinar with Katheren Leitner to discover the impact indoor air quality has on our health.

7-8pm, Thur 9 May. Find out more & register HERE.

Manawatu Feilding eHaus Pacific

12,399
kg
79%

Presenting an impressive fusion of aesthetics and functionality, this home boasts a simplistic yet elegant layout. The lower level hosts the master suite with ensuite, a study, and an open plan living and kitchen
area. Upstairs, two additional bedrooms, a bathroom, and a media room offer versatile living spaces across a total floor area of 251sqm. Noteworthy is the abundant storage cleverly integrated into both the garage and living spaces, ensuring a tidy living.

This exceptional home has garnered accolades, including a Gold and Category Winner at the Registered Master Builder 2021 House of the Year Competition in Manawatu. Additionally, it was honoured among the National Top 100 homes for 2021, underscoring its excellence in design and craftsmanship.

Extraordinary heat energy savings.

Every one of our projects are energy modelled using the Passive House Planning Package (PHPP). It's through this powerfully clever tool that we can accurately calculate just how much heat energy every eHaus will save when compared to a similarly- sized typical new home, built in the same climate region.

Learn More
79%
12,399

This project is making significant carbon savings for a better environment.

We believe that our homes should have a big impact on the way we live, but little impact on the land. We've calculated the amount of carbon our homes have saved through energy efficiency from move in day 'til now. At their core, eHaus' are built with the elimination of carbon emissions in mind - so we're not only creating healthy, comfy & high performing homes, but spaces that don't cost the earth.

Learn More

Meet the team of designers and builders behind this project

Our eHaus team is made up of some of the country's best Passive House builders, architects and designers who are redefining the way kiwis live one home at a time. Our team of professionals work together to see your dreams come to reality.
Experience
See this eHaus for yourself
Contact us

Design Components

Floor
Fully insulated concrete pad with a U-value of 0.182 W/(m²K)
Wall
140mm timber frame U-value of 0.263 W/(m²K)
Roof
Double layer of fibreglass insulation U-value of 0.131 W/(m²K)
Window Joinery Frame
Nebulite – Thermally broken aluminium. Uf value 4.30 W/(m²K)
Glazing
Double Glazed Low G Argon Ug value 1.10 W/(m²K) – g-value = 37%
Ventilation
Zehnder Q350 ST MHRV
Hot Water
Bosch Compress 3000 – 270L capacity Hot Water heat pump
Heating/Cooling
2.5 kW heat pump air conditioned unit

Performance Specs

Heating Demand: 29.8 kWh/m²/year
Heating Load: 19.7 W/m²
Frequency of Overheating: 1.9 % year over 25C
TFA: 168.8 m²
Form Factor: 3.47
Air Leakage@50Pa: 1.64 ACH
PER Demand: 44 kWh/m²/year

Consultant

Maria Rei

Certifier

N/A

We've picked out a few of our other projects you might like

View all projects
We believe all great projects start with a great conversation. Get in touch with us to get your eHaus project started with a free, no obligation consultation.
Book a free consultation
cross