Kapiti Waikanae CentralNon-certified, eHaus Euro, PHI Low Energy

Discover

This a small but perfectly formed eHaus is nestled in a private retreat away from the business of life. It has all you need including 3 bedrooms and an amazing private outdoor area linking directly to the internal living space. With all of the normal eHaus features and some extras this home has a very light footprint on the planet and generates most of the electricity that is needed to run the home through the year.

"From the time we had our kick off meeting… About 20th March... basically we came out of Consent on the 21st of July, so been a four month process. Working together between the design and the builder and ourselves, very tightly together, has been the right way to go"– Robin

5,162

This project is making significant carbon savings for a better environment.

We believe that our homes should have a big impact on the way we live, but little impact on the land. We've calculated the amount of carbon our homes have saved through energy efficiency from move in day 'til now. At their core, eHaus' are built with the elimination of carbon emissions in mind - so we're not only creating healthy, comfy & high performing homes, but spaces that don't cost the earth.

Learn More

Meet the team of designers and builders behind this project

Our eHaus team is made up of some of the country's best Passive House builders, architects and designers who are redefining the way kiwis live one home at a time. Our team of professionals work together to see your dreams come to reality.
Experience
See this eHaus for yourself
Contact us

Design Components

Power Generation
3 kW Solar PV system
Floor
Fully insulated concrete pad with a U-value of 0.184 W/(m²K)
Wall
140mm timber frame with service cavity U-value of 0.223 W/(m²K)
Roof
Double layer of fibreglass insulation U-value of 0.138 W/(m²K)
Window Joinery Frame
Advanced Windows NZ- uPVC – Uf value 1.50 W/(m²K)
Glazing
Double glazed Argon Ug value = 1.1 W/(m²K) g-value = 61%
Ventilation
Zehnder Comfo Air 350 LH MHRV
Hot Water
Bosch Compress 3000 – 270L capacity hot water heat pump
Heating/Cooling
DF 960 Gas fire. Under tile heating mat on ensuite and bathroom

Performance Specs

Heating Demand: 24.0 kWh/m²/yr
Heating Load: 15.1 W/m²
Frequency of Overheating: 1%
TFA: 125.97 m²
Form Factor: 3.93
Air Leakage@50Pa: 0.80 ACH
PER Demand: 33 kWh/m²/y

Consultant

Jon Iliffe

Certifier

N/A

We've picked out a few of our other projects you might like

View all projects
Ready to start your eHaus journey?
eHaus
400 Victoria Ave, Whanganui
We believe all great projects start with a great conversation. Get in touch with us to get your eHaus project started with a free, no obligation consultation.
Book a free consultation
© ECOBUILD DEVELOPMENTS 2019 - 2021