Waikato Tamahere Non-certified, eHaus Euro, Passive House Classic

Discover

This four bedroom eHaus Euro fits to the natural contours of the site with north facing windows making the most of the rural views. The high performance wood aluminium European joinery is a feature throughout the home and further timber features are echoed in the extensive built in joinery in both the kitchen and living areas.

This home has a 5 kw PV solar system, supplying the home, which is also battery ready for the future. Aluminium shading screens have been added to gable ends, complementing the dark cedar and block exterior cladding. Extensive timber decking areas on the north and east allow easy indoor/outdoor living with a sheltered enclosure to enjoy the outdoor fireplace.

3,705

This project is making significant carbon savings for a better environment.

We believe that our homes should have a big impact on the way we live, but little impact on the land. We've calculated the amount of carbon our homes have saved through energy efficiency from move in day 'til now. At their core, eHaus' are built with the elimination of carbon emissions in mind - so we're not only creating healthy, comfy & high performing homes, but spaces that don't cost the earth.

Learn More

Meet the team of designers and builders behind this project

Our eHaus team is made up of some of the country's best Passive House builders, architects and designers who are redefining the way kiwis live one home at a time. Our team of professionals work together to see your dreams come to reality.
Experience
See this eHaus for yourself
Contact us

Design Components

Floor
Fully insulated concrete pad with a U-value of 0.182 W/(m²K)
Wall
140mm timber frame with service cavity U-value of 0.223 W/(m²K)
Roof
Double layer of fibreglass insulation U-value of 0.131 W/(m²K)
Window Joinery Frame
Dopfner -Wood- aluminium- Uf value = 1.3 W/(m²K)
Glazing
Double Glazed  Argon Ug value=1.12 W/(m²K) g- value = 61%
Ventilation
Zehnder ComfoAir Q450 MHRV
Hot Water
Bosch Compress 3000 – 270L capacity heat pump hot water cylinder
Heating/Cooling
Two Air Conditioned units installed: Fujitsu ASTG12KMTC Lifestyle Series 3.7KW, Fujitsu ASTG22KMTC Lifestyle Hi-wall 6/7.2kw

Performance Specs

Heating Demand: 13.6 kWh/m²/yr
Heating Load: 12.7 W/m²
Frequency of Overheating: 2.6% year over 25C
TFA: 215.2 m²
Form Factor: 4.09
Air Leakage@50Pa: 0.5ACH
PER Demand: 30 kWh/m²/yr

Consultant

Maria Rei

Certifier

N/A

We've picked out a few of our other projects you might like

View all projects
Ready to start your eHaus journey?
eHaus
400 Victoria Ave, Whanganui
We believe all great projects start with a great conversation. Get in touch with us to get your eHaus project started with a free, no obligation consultation.
Book a free consultation
© ECOBUILD DEVELOPMENTS 2019 - 2021