Breath of fresh air: Join our free webinar with Katheren Leitner to discover the impact indoor air quality has on our health.

7-8pm, Thur 9 May. Find out more & register HERE.

Hawkes Bay Te Mata 2 eHaus Euro, Certified, Passive House Classic

9,819
kg
89%

A single level family home nestled below the magnificent Te Mata Peak in Havelock North. The client has give a particular focus on future proofing this home with on site power generation, power storage and water harvesting. Although grid tied the power bills will amount to a few coffees a month in winter and  pay for a few coffees in the summer!  This technology coupled with the Passive House standard ensures year round comfort for the life of this eHaus.

Extraordinary heat energy savings.

Every one of our projects are energy modelled using the Passive House Planning Package (PHPP). It's through this powerfully clever tool that we can accurately calculate just how much heat energy every eHaus will save when compared to a similarly- sized typical new home, built in the same climate region.

Learn More
89%
9,819

This project is making significant carbon savings for a better environment.

We believe that our homes should have a big impact on the way we live, but little impact on the land. We've calculated the amount of carbon our homes have saved through energy efficiency from move in day 'til now. At their core, eHaus' are built with the elimination of carbon emissions in mind - so we're not only creating healthy, comfy & high performing homes, but spaces that don't cost the earth.

Learn More

Meet the team of designers and builders behind this project

Our eHaus team is made up of some of the country's best Passive House builders, architects and designers who are redefining the way kiwis live one home at a time. Our team of professionals work together to see your dreams come to reality.
Experience
See this eHaus for yourself
Contact us

Design Components

Floor
Fully insulated concrete pad with a U-value of 0.182 W/(m²K)
Wall
140mm timber frame U-value of 0.222 W/(m²K)
Roof
Double layer of fibreglass insulation with a U-value of 0.128 W/(m²K)
WINDOW JOINERY FRAME
Thermadura- NatureLine 90- Wood- Uf value = 1.29 W/(m²K)
Glazing
Double Glazed Argon Ug value=1.14 W/(m²K) g- value = 64%
Ventilation
Zehnder ComfoAir Q600 MHRV

Performance Specs

Heating Demand: 15 kWh/m²/yr
Heating Load: 9W/m²
Frequency of Overheating: 1%
TFA: 231m²
Form Factor: 3.56
Air Leakage@50Pa: 0.6 ACH
Per Demand: 25 kWh/m²/yr

Consultant

Jon Iliffe

Certifier

Sustainable Engineering - Sara Wareing

We've picked out a few of our other projects you might like

View all projects
We believe all great projects start with a great conversation. Get in touch with us to get your eHaus project started with a free, no obligation consultation.
Book a free consultation